Taco zvc zone control erie poptop zone valves zone valves, zone controls. Buy products related to zone valves and see what customers say about zone valves on. Wiring a taco zone sentry zone valve to replace a flair or taco 3 wire valve. How to wire taco 570 series zone valve to a honeywell. The taco zone valve controls should be used in coordination with 2, 3, or 4 wire zone valves. The taco heat gard thermostatic valves keep a heating system comfort balanced by eliminating cold spots and overheating. Honeywell zone valve v8043f1036 wiring diagram free. Engineered for reliability, taco heat motor zone valves provide a time. The right motor terminal must be connected to terminal 1 on the zone valve. Installers appreciate the open lever and twistoff head that makes installation and service easy.
Taco 573 heat motor zone valve offers a convenient way to create individual zones in radiant heating or hydronic heating system. Typical installation diagrams individual room control. A zone valve is a specific type of valve used to control the flow of water or steam in a hydronic. Taco zone sentry zone valves provide onoff, normally open or normally closed control in both open and closed hydronic systems. Taco zone controls wiring guide pages switching relays single zone wiring 2 12. Zone valve controls taco zone valve controls work with two, three, or four wire zone valves. When the wiring is complete for all four zone thermostats and zone valves, each thermostat will be able to power up its own zone valve on a call for heat.
How to wire taco 570 series zone valve to a honeywell l7224a,c aquastat controller with a thermostat already on tt answered by a verified hvac technician. Move the manual opening lever on the side of the actuator. Zone valve controls non exp connected together with priority 22 27. All the end switches in a system are wired in parallel so that a call for heat from any zone powers the burner and circulator. The explanation below and associated diagrams explain stepbystep the operation of the zone valve. The water quality in the heating system had seized the pivots on the old zone valves, so they.
Photo below, reader contributed illustrates typical wiring connection at two zone valves. The tacozone valve is an electricity operated valve used for zone control of hydronic. Heat motor zone valves start, stop or divert flow through the system with a single pump using multiple heat motor zone valves and a single pump, you can start, stop or divert flow through the system to provide individual room or area comfort control and energy savings. Taco 3 wire zone valve wiring diagram free wiring diagram. Pdf models 555573 1983 heat motor zone valves,models 555, 556. Johnstone supply is a leading wholesale distributor for multiple leading brands of hvacr equipment, parts and supplies available and instock at local branches. The zone valve works with hot water or steambased baseboard heating systems. For our purposes, the red end switch wires on the zone.
When connecting the taco 570 zone valve to the caleffi zone relay, the. When power is applied, the motor should open the zone. A control box is wired to thermostats in your house and controls the zone valves. When a signal is sent from the zone s thermostat to the valve a wax piece inside the valve heats and expands. Zone valve does not work jammed, stuck, does not open in response to call for heat at that zone. They are engineered for reliability and built with all the quality you expect from taco. Heat motor zone valves zone valve operation and wiring there have always been questions surrounding how the 3 wire terminal block design of the taco heat motor zone valve works. Honeywell zone valve v8043f1036 wiring diagram collections of honeywell actuator wiring diagram wire diagram wiring diagram. There are millions of taco zone valves in use and they are the industrys top choice for consistent performance. Wiring diagram using a zone valve with a 24v thermostat. State supply offers taco electric and nonelectric zone valves and power head units for taco electric zone valves. Taco 570 gold series zone valves, sentry series, 560 series and taco geothermal series. White black r 110v power source 24v thermostat pn 8200008 rc y b o rh g w zone valve. Honeywell actuator wiring diagram beautiful unusual 3 port valve.
Taco zone sentry zone valve taco 570 series l1 hot l2 thermostat to t terminals motor end switch 1 2 3 flair l1 hot l2 thermostat to t terminals motor. The head on yours may be blue green instead of gold or brown. Utilizing one pump along with multiple zone valves. With its compact design and front mounted diagnostic lights. The taco electronic ball valve ebv zone valve is a gear driven, capacitor powered valve.
Zone controls, switching relays with powerport options and expandable to 20 zones, zone valve controlswith powerport options and. It is a four wire capacitor start type of zone valve with very low amperage draw. Its proven design and reliable operation make it the simplest way to prevent energy waste and reduce heating costs. The other yellow zone valve motor wire connects to the c found on the same transformer. Ebv technology replaces the typical spring mechanical energy storage device with a prostar capacitor electronic energy storage device for returning the valve to its normal position. Taco zone valves 570 taco zone valves taco zone sentry. A zone valve helps control the heat from a thermostat for an area of your home, such as a bedroom or living room. There are by the way a couple of tricky little wiring scenarios with the three wire taco zone valves. The taco 570 zone valve presents a unique wiring challenge. Taco zone valves are designed to create and control individual zones or isolate equipment in a hydronic heating system. Designed and engineered for reliability and built with all the quality you expect from taco, these zone and flow control valves are used to create and control individual zones or isolate equipment in a hydronic heating system. This valve is used to control the flow to a fan coil or terminal heating unit.
As the air temperature at the thermostat drops to the thermostat. Wiring a taco zone sentry zone valve to replace a honeywell, erie or sparco valve. Taco zone valve wiring, voltage and water flow tested and proved. Properly wired, the individual thermostat calls for heat, the zone valve opens, when the valve is fully open an end switch in the valve connects a second pair of wires that turn on the circulator pump back at the boiler. Zone and flow control valves taco comfort solutions. How to wire a system circulator to a taco zone valve control zvc watch as the method of wiring a system circulator to a zone valve. Diverting valves operate the same way, except that the ball closes the alternate port when the valve opens. Wiring diagram using a z one valve with a 24v thermostat and a transformer for illustration purposes only. My existing setup was 3 taco 5712 valves two for heat zones and one for domestic hot water. A wiring diagram is a simplified standard photographic representation of an electrical circuit. In addition, we have replaced the typical synchronous ac motor. The valves can be used in a wide variety of heating and noncondensing cooling applications, primarily designed for use with baseboard, fan coils, radiators, convectors, air handlers, heat. I am using a honeywell rth4300b thermostat for both the heat and ac in this zone.
Zone valve operation and wiring there have always been questions surrounding how the 3 wire terminal block design of the taco heat motor zone valve works. As for the esp taco zone valve that is totally differetn from the 555 heads. Taco zone valves, taco 570, taco 560, taco e series, taco. The unique end switch design permits control of the heat pump by the valve, allowing cold water into the coil before the heat pump starts. Utilizing one pump along with multiple zone valves, flow can be started. Honeywell mut meccanica orkli siemens taco valemo controls. When the thermostat calls for heat, both the appropriate zone valve and yellow indicator lights are energized. Wire diagram for taco zone valves for hydronic heating systems. I have added a 4th taco 5712 flow valve for the upstairs zone. Taco zone valve controls taco zone valve controls zvcs simplify wiring complicated controls. The explana tion below and associated diagrams explain stepbystep the operation of the zone valve.
The taco sr501 switching relays layout makes short work of any job. Installers prefer taco zone valves for their quiet and dependable operation. When a signal is sent from the zone s thermostat to the valve a wax piece inside the valve. If the thermostat is turned all the way up and you do not have heat in that zone. Heavy bronze body with sweat or threaded connections for heat pump and geothermal applications, taco offers l37906, which has corrosionresistant internal parts designed to close against high head pumps 150 head. Taco product information switching relays product no.
Good installation details install a zone valve on the return side of the heating piping loop where it will be exposed to lower and thus less stressful temperatures. Other suitable two wire spst thermostats may also be used if heat anticipator can. When the zone valve is fully opened, the end switch relay and red indicator light is then energized. This cycle continues until the the thermostat is satisfied. Taco electric and nonelectric zone valves for heating. Hydronic diagram is for illustration purposes only, some components have. Taco heat motor zone valves provide a convenient way to create individual zones or equipment isolation in a hydronic heating system. For electrical zone valves, the motor is often a small shadedpole. Taco makes a range of heating and cooling products, including a taco zone valve. Using a single circulator pump with multiple zone valves, allows to startstop.